Ultraviolet Lamp
TUV T8 Xtra

TUV T8 Xtra

Product Introduction and Application

TUV T8 Xtra lamps are double-ended UVC (germicidal) lamps used in professional water and air disinfection units. Thanks to the unique X-technology TUV T8 Xtra lamps even double the life of conventional types. This extra long and reliable lifetime is even up to 36.000 hours when the lamps are operated on HF Gear. As a result these lamps need to be replaced less often, significantly reducing cost and disruption. Thanks to the reliable lifetime, maintenance can be planned in advance.

Main Applications:
• Air disinfection systems in professional applications such as universities, hospitals, jails and laboratories.
• Upper air and whole room disinfection equipment in hospitals, intensive care units and surgery rooms.
• Areas where absolute security of effective disinfection is crucial.
• Areas where maintenance costs are high (e.g. high ceilings, difficult access) and/or disruptive costs are high (e.g. areas like operating theatres where lamp failure is unacceptable for safety reasons.

Features:
• Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes.
• Protective inside coating ensures almost constant UV output over the complete lifetime of the lamp.
• Long lifetime of 36,000 hours* (double the life of conventional types) thanks to unique X-technology.
• High reliability with the lowest percentage of lamps that fail prematurely in the market (90% of all lamps still operate on full output and quality after 30,000 hours*).
• Special lamp glass filters out the 185 nm ozone-forming radiation.
• High Output versions available for optimum UVC output per lamp length, allowing for reduction of system size.
• Warning sign on lamp indicates that the lamp radiates UVC.
* based on operation on a Philips electronic driver .

Benefits:
• Security of effective disinfection over the useful lifetime of the lamp.
• Reduction of maintenance costs and disruption thanks to doubled lifetime.
• Maintenance can be planned in advance, virtually eliminating the need for expensive spot replacement of prematurely failed lamps
• High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection.
• Good environmental choice because of lowest amount of mercury.
• Directly replaces conventional T8 lamps, so it is not required to modify the system to enjoy the benefits.

Specification
Type Cap-Base Dim. No. Technical Lamp Wattage (W) Lamp Voltage(V) UVC 100 on EM Gear (h) UVC 100 on HF Gear (h) Lamp Current (A) Useful Life on EM gear (h) Useful Life on HF gear (h) Depreciation at useful lifetime(%)
TUV 15W Xtra G13 1 15.9 54.0 4.9 5.1 0.335 18000 36000 10
TUV 25W Xtra G13 1 25.5 48.0 7.0 7.5 0.612 18000 36000 15
TUV 30W Xtra G13 2 30.0 102.0 12.0 13.1 0.365 18000 36000 10
TUV 36W Xtra G13 3 36.0 103.0 15.0 14.7 0.440 18000 36000 10
TUV 55W Xtra G13 2 54.0 86.0 17.5 19.6 0.770 18000 36000 10
TUV 75W Xtra G13 3 75.0 110.0 25.5 28.1 0.835 18000 36000 10

TUV T8 Xtra
G13
Dim. A B B C D1
no. max. min. max. max. max.
1 437.4 442.1 444.5 451.6 28
2 894.6 899.3 901.7 908.8 28
3 1119.4 1204.1 1206.5 1213.6 28

Infrared Lamp :: Halogen Infrared Lamp | White Coated Infrared Lamp | Gold Coated Infrared Lamp | Transparent Infrared Lamp | Ruby Infrared Lamp | Jacketed Infrared Lamp | Hysiotherapy Infrared Lamp | Industrial Infrared Lamp | Carbon Fiber Infrared Lamp | Woven Carbon Fiber Infrared Lamp | Ruby Carbon Fiber Infrared Lamp | Reflective Carbon Fiber Infrared Lamp | Transparent Carbon Fiber Infrared Lamp | Halogen Bulb | PAR38 Infrared Bulb | R125 Infrared Bulb| BR38 Infrared Bulb | R63 Infrared Bulb | R80 Infrared Bulb | R95 Infrared Bulb | Infrared Patio Heater | Infrared Paint Dryer

Ultraviolet Lamp :: Cold Cathode Quartz UV Lamp | Hot Cathode Quartz UV Lamp | UVA Lamp | UVB Lamp | UVC Lamp | Special Lamp

LED Lamp :: LED Bridge Guardrail Lamp | LED Bulb | LED Candle Bulb | LED PAR Bulb | LED Spotlight | LED Strip | LED Down Light | LED Ceiling Light | LED Panel Light | LED High Bay Light | LED Filament Lamp | LED Wall Washer | LED Grow Light | LED Tunnel Light | LED Underground Light | LED Underwater Light | LED Tube Light

Halogen Lamp :: PAR38 Halogen Lamp | PAR56 Halogen Lamp | PAR64 Halogen Lamp | Eco Halogen Bulb | Tracklight Halogen Lamp | Double Ended Halogen Lamp | Single Ended Halogen Lamp | AR Halogen Lamp | Floodlight Halogen Lamp | Bi-Pin Halogen Lamp | Reflector Halogen Lamp

HID Lamp :: Metal Halide Lamp | ED-Type Metal Halide Lamp| Tubular Metal Halide Lamp | Ceramic Metal Halide Lamp | Fishing Luring Metal Halide Lamp | Double Ended Metal Halide Lamp | G12 Metal Halide Lamp | Pulse Start Metal Halide Lamp | Color Output Metal Halide Lamp | PAR Metal Halide Lamp | Aquarium Metal Halide Lamp | Double Arc Tube Metal Halide Lamp| Sodium Lamp | American Standard High Pressure Sodium Lamp | European Standard High Pressure Sodium Lamp | High Efficiency High Pressure Sodium Lamp | Double Arc Tube High Pressure Sodium Lamp | Inner Ignition High Pressure Sodium Lamp | Double Ended High Pressure Sodium Lamp | Mercury Lamp | High Pressure Mercury Lamp | Blended Mercury Lamp

Compact Fluorescent Lamp :: Spiral Compact Fluorescent Lamp | U Compact Fluorescent Lamp | Covered Compact Fluorescent Lamp | Tubular Linear Compact Fluorescent Lamp | Colored Compact Fluorescent Lamp | G9 Compact Fluorescent Lamp | GU10 Compact Fluorescent Lamp | GX53 Compact Fluorescent Lamp | PAR Compact Fluorescent Lamp | Reflector Compact Fluorescent Lamp | Plug-In Compact Fluorescent Lamp | Candle Compact Fluorescent Lamp | High Power Compact Fluorescent Lamp | Globle Compact Fluorescent Lamp | Incandescent Compact Fluorescent Lamp

Fluorescent Lamp :: T4 Fluorescent Lamp | T5 Fluorescent Tube Lamp | T6 Fluorescent Tube Lamp | T8 Fluorescent Tube Lamp | 2D Tube Fluorescent Lamp | Circular Fluorescent Lamp

Incandescent Lamp :: GLS Lamp | Global Lamp | Reflector Lamp | Candle Lamp | Twisted Lamp | Mushroom Lamp | Tailed Lamp | Indicator Lamp | Hammer Lamp | Flickering Flame Lamp